Products

33KV Transformer

33KV Transformer

33KV 11KV Transformer
Step Down Transformer 33KV To 11KV
Power Transformer 33KV 11KV
33/11 KV Power Transformer
33KV To 11KV Transformer
33/11KV Transformer
Step Up Transformer 11KV To 33KV
11KV To 33KV Transformer

Features

33 KV Transformer Specification
Rated Voltage: 33 KV
Frequency: 50 Hz/60 Hz
Winding Material: Copper
Cooling Method: ONAN/ONAF
Minimum Ambient Temperature: -10°C
Maximum Ambient Temperature: 40°C
Altitude: up to 1,000 meters above sea level

 

33KV Transformer Parameter Datasheet

33KV Transformer Rating (KVA)

HV

LV

VECTOR GROUP

Impedance voltage

No-load loss (KW)

Load loss (KW)

No-load Current (%)

33KV Transformer Size

33KV Transformer Weight

630

33KV

35KV

34.5KV

38.5KV

3.15KV

6.3KV

6.6KV

10.5KV

11KV

11.5KV

Yd11

6.5%

1.04

1.04

1.1

As per final product

As per final product

800

1.23

1.23

1

1000

1.44

1.44

1

1250

1.76

1.76

0.9

1600

2.12

2.12

0.8

2000

2.72

2.72

0.7

2500

3.2

3.2

0.6

3150

7%

3.8

3.8

0.56

4000

4.52

4.52

0.56

5000

5.4

5.4

0.48

6300

7.5%

6.56

6.56

0.48

8000

9

9

0.42

10000

10.88

10.88

0.42

12500

Ynd11

8%

12.6

12.6

0.4

16000

15.2

15.2

0.4

20000

18

18

0.4

25000

21.28

21.28

0.32

31500

25.28

25.28

0.32

 

Benefits:
- High efficiency
- Excellent performance
- Robust and durable construction
- Easy to maintain
- Safe and reliable operation
- Low noise level

 

Applications:
- Power plants
- Electrical grid stations
- Industrial plants
- Commercial buildings
- Hospitals and healthcare facilities
- Data centers.

 

FAQ
1.How To Install 33KV Transformer?
33KV transformer installation steps is as below
1. Choose a suitable location for the transformer installation.
2. Prepare the foundation for transformer and make sure it is level and firm.
3. Install the transformer on the foundation and connect it to the high voltage transmission line.
4. Install the medium voltage side of the transformer to the distribution line.
5. Connect the transformer to the grounding system.
6. Install the control panel and connect the control wiring.
7. Perform testing to ensure the transformer is operating correctly.

2.Why We Use 33/11KV Transformer?
A 33/11KV transformer is commonly used in electrical power systems to step down the high voltage of 33KV to 11KV for distribution to local areas. This is because 11KV is a more suitable voltage for powering homes and businesses. Using a transformer to step down the voltage also helps to reduce power losses during transmission over long distances. Additionally, 33KV is considered to be a high voltage that requires specialized equipment for safety and maintenance, whereas 11KV is a more easily managed voltage range. Therefore, a 33/11KV transformer is a common and efficient solution for managing electrical power distribution to local areas.

3.Difference Between 33KV And 11KV Transformer?
A: The main difference between a 33KV and 11KV transformer is the voltage they are designed to handle. A 33KV transformer is designed to handle higher voltages, while an 11KV transformer is designed to handle lower voltages. In addition, due to the higher voltage rating, a 33KV transformer is typically larger and more expensive than an 11KV transformer.

Hot Tags: 33kv transformer, China, suppliers, manufacturers, factory, buy, price, for sale, transformer industrial, 100kva dry transformer, 300kva transformer, 100 kva single phase pad mounted transformer, 75kva dry type transformer, 11kv to 380v transformer

You Might Also Like

(0/10)

clearall